Skip to content

multiFiltrate

multiFiltrate Acute Therapy System

Your choice for optimal therapy

  • Ergonomic and intuitive
  • Safe and easy handling
  • Full range of renal replacement therapies
  • In combination with the advantages of Ci-Ca®

Key features

You have the choice

  • Heparin or citrate anticoagulation – multiFiltrate Ci-Ca® offers both options
  • Disposables tailored to your treatment – saves costs

Our experienced staff and tested and proven training concept support you with initial and ongoing training.

multiFiltrate acute therapy machine with Ci-Ca® module

multiFiltrate acute therapy machine

 

multiFiltrate acute therapy options

  • Ci-Ca® CVVHD
  • Ci-Ca® CVVHD EMiC®2
  • Ci-Ca® postCVVHDF
  • CVVHD
  • CVVHD EMiC®2
  • CVVHDF
  • CVVH
  • Pre-Post CVVH
  • MPS
  • SCUF
  • HP
  • Pediatric CVVH / CVVHD

 

multiFiltrate Ci-Ca® contains

  • 6 roller tube pumps
  • 2 integrated heating systems for solutions
  • 1 integrated heparin pump
  • 1 robust and highly accurate weighing system
Simple handling
  • Cassette system for blood and filtrate tubing
  • Color-coded tubing systems
  • Ci-Ca® module for regional citrate anticoagulation
  • Step-by-step screen instructions lead the user through the preparation phase

Reliable, even in difficult situations

  • In the case of an alarm, the multiFiltrate assists you in finding possible causes, automatically
  • It makes reasonable recommendations on how to address the fault as quickly as possible
  • Up to 3,500 treatment-related parameters and events can be stored during treatment
Easy bag change
  • The scales can be loaded with up to 24 kg of fresh substitution or dialysate solution
  • Safety: Color-coded connectors for dialysate and substituate fluids guide the user to avoid mix-up of bags
  • Easy: Load more than one bag at the same time on each upper scale
  • Citrate infusion continues during regular dialysate, substituate and filtrate bag changes contributing to:
    • Less clotting
    • Longer filter lifespan 
Back of multiFiltrate acute therapy machine

Back of multiFiltrate acute therapy machine

Standard solution Connector for multiFiltrate

Solution connector for standard therapies on multiFiltrate acute therapy machine

Ci-Ca® solution Connector for multiFiltrate

Solution connector for Ci-Ca therapies on multiFiltrate acute therapy machine

Therapy kits

Complete kits for multiFiltrate

The multiFiltrate kits contain:

  • multiFiltrate cassette (AV-set and filtrate system pre-assembled) or volume-reduced midi AV-set or pediatric system with very low extracorporeal blood volume
  • Substituate and/or dialysate system (depends on therapy mode)
  • Hemofilter or plasmafilter
     

A multiFiltrate cassette consists of arterial, venous, and filtrate lines. This allows easy installation of the tubing system required for each treatment.

The combination of the multiFiltrate cassette with treatment-specific tubing systems enables the multiFiltrate to be set up quickly and efficiently.

Treatment kit options for multiFiltrate therapies

Ci-Ca® CVVHD

Ci-Ca® CVVHD

  • multiFiltrate – kit Ci-Ca CVVHD 1000
  • multiFiltrate – Kit Ci-Ca CVVHD EMiC2
Ci-Ca® post-CVVHDF schema

Ci-Ca post-CVVHDF:

  • multiFiltrate – Kit Ci-Ca postCVVHDF 1000
CVVHDF schema

CVVHDF:

  • multiFiltrate – Kit 8 CVVHDF 1000
  • multiFiltrate – Kit 4 CVVHDF 600
  • multiFiltrate – Kit midi CVVHDF 400
alt="CVVHD schema"

CVVHD:

  • multiFiltrate – Kit CVVHD EMiC®2
  • multiFiltrate – Kit 3 CVVHD 600
Pre-post CVVH schema

Pre-post CVVH:

  • multiFiltrate – Kit 7 HV-CVVH 1000 (High-Volume CVVH)
  • multiFiltrate – Kit 5 pre-post CVVH 600 (High-Volume CVVH)
CVVH schema

CVVH:

  • multiFiltrate – Kit 9 CVVH 1000
  • multiFiltrate – Kit 2 CVVH 600
MPS schema

MPS:

  • multiFiltrate – Kit 16 MPS P2dry
  • multiFiltrate – Kit MPS P1dry
HP schema

HP:

  • All treatment kits
     

Hemoperfusion as blood purification therapy is available with the multiFiltrate simply by using a multiFiltrate cassette and an adequate adsorption cartridge.

pediatric CVVHD schema

Pediatric CVVHD:

  • multiFiltrate – Kit paed CRRT/SCUF
     

The Ultraflux® AVpaed hemofilter combined with special volume reduced lines is used to perform pediatric CVVHD.

Pediatric CVVH schema

Pediatric CVVH:

  • multiFiltrate – Kit paed CRRT/SCUF
     

The Ultraflux® AVpaed hemofilter combined with special volume reduced lines is used to perform pediatric CVVH in post- or predilution.

SCUF schema

SCUF:

  • multiFiltrate – Kit paed CRRT/SCUF
     

The combination of a small Ultraflux® AV hemofilter and the pediatric lines with very low extracorporeal blood volume enables the user to perform an efficient continuous ultrafiltration for adult and pediatric patients.

Kit guideline chart Tubing system CVVHD CVVHDF CVVH MPS SCUF HP
multiFiltrate – Kit Ci-Ca® CVVHD 1000 cassette o          
multiFiltrate – Kit Ci-Ca® CVVHD EMiC®2 cassette o          
multiFiltrate – Kit Ci-Ca® postCVVHDF 1000 cassette   o        
multiFiltrate – Kit 8 CVVHDF 1000 cassette x o x     x
multiFiltrate – Kit 4 CVVHDF 1000 cassette x o x     x
multiFiltrate – Kit midi CVVHDF 400 midl x o x     x
multiFiltrate – Kit 9 CVVH 1000 cassette     o     x
multiFiltrate – Kit 2 CVVH 600 cassette     o     x
multiFiltrate – Kit 7 HV-CVVH 1000 cassette     o     x
multiFiltrate – Kit 5 pre-post CWH 600 cassette     o     x
multiFiltrate – Kit CWHD EMC®2 cassette o         x
multiFiltrate – Kit 3 CWHD 600 cassette o         x
multiFiltrate – Kit paed CRRT/SCUF paed o   o   o  
multiFiltrate – Kit 16 MPS P2dry cassette       o   x
multiFiltrate – Kit 16 IS MPS P2dry         o   x
multiFiltrate – Kit MPS P1dry midl       o   x

o = Dedicated usage
x = Alternative usage - some of the included lines will not be used

Standard settings for the multiFiltrate Ci-Ca® postCVVHDF

Display of the multiFiltrate Ci-Ca® postCVVHDF during the treatment, illustrated with the standard settings

Technology

Well-designed user interface on the multiFiltrate
  • Step-by-step setup instructions
  • Easy guidance for bag changes
  • Standard settings to ease startup
  • No manual calculations necessary

Ci-Ca® therapy with integrated Ci-Ca® module

  • Fulfils the highest clinical and technical standards
  • Ci-Ca® tubes guided on the cassette
  • Color coding for intuitive setup
  • Different connectors for citrate and calcium to avoid mix-up of bags
  • Citrate and calcium flow coupled with blood and filtrate flows
  • Integrated in balancing system

Ci-Ca® tubes guided on the cassette

Ci-Ca® tubes guided on the cassette

Citrate and calcium flow coupled with blood and filtrate flows

Citrate and calcium infusion for multiFiltrate

Citrate and calcium infusion always fed into the correct branch of the catheter due to fixed connections

multiDataLink

You can easily connect the multiFiltrate to the IT network and patient data management system (PDMS) in your hospital. This allows you to transfer treatment settings automatically to the IT network.

The benefits

  • Quality assurance with assessment of treatment data
  • Detailed documentation, such as display of individual fluid balances
  • Data retrieval at multiple locations using network interfaces

Advanced technology means

  • Programmed pre-set therapy settings
  • Intelligent and intuitive user interface
  • Patient blood detection using an optical blood sensor
  • Precise fluid balance monitoring (with balance accumulated since last reading)
  • Pressure monitoring of the entire extracorporeal circuit
  • Effective integrated temperature control
  • Reliable operation, optimized for use of central venous catheters
  • Structured alarm handling with integrated help functions
  • Emergency stop for immediate halting of all pumps

Complex system, simple service

The multiFiltrate is as simple to maintain as it is to use. Diagnostic programs specific to the device as well as our well-trained technicians assist in maintenance. Special maintenance actions guarantee above-average equipment availability. This saves you costs and ensures satisfaction.

Related content
Continuous renal replacement therapy (CRRT) setups

Different options as standard therapies for acute kidney injury.